Class | Installation cable | Nominal cross-section concentric conductor | 0 mm2 |
Series / program | YMvKas | Arming | Yes |
Conductor material | Copper, bare | Outer jacket material | PVC |
Nominal conductor cross-section | 2.5 mm2 | Jacket color | Grey |
Conductor structure | Class 1 = solid | Halogene free according to EN 50267-2-2 | No |
Conductor shape | Round | Fire retardant according to EN 60332-3-24 | Yes |
Number of cores | 4 | Low smoke according to EN 61034-2 | No |
Insulation | XLPE (VPE) | Insulation retention | No |
Conductor coding | Color | Functional safety | No |
Yellow / green wire | No | Outside diamter approx |
15.5 mm |
Screen | Yes | Max. permisble conductor temperature | 90 °C |
Litze | Yes | Min / Max installation temperature | 0 - 60 °C |
Numbers of auxiliary cores | 0 | Min / Max operating temperature | -20 - 90 °C |
Nominal cross-section conductor | 0 mm2 | Nominal voltage U0 | 0.6 kV |
Lead jacket | No | Nominal voltage U | 1 kV |
Concentric conductor | None |
YMVkas cable 4 x 2,5 mm
Item No.080101259
Royal Brinkman does not provide their services to any company outside of the horticulture.
✔ Login and request a quotation for multiple products
✔ Worldwide delivery options
✔ Premium products for your cultivation
Description
Class | Installation cable | Nominal cross-section concentric conductor | 0 mm2 |
Series / program | YMvKas | Arming | Yes |
Conductor material | Copper, bare | Outer jacket material | PVC |
Nominal conductor cross-section | 2.5 mm2 | Jacket color | Grey |
Conductor structure | Class 1 = solid | Halogene free according to EN 50267-2-2 | No |
Conductor shape | Round | Fire retardant according to EN 60332-3-24 | Yes |
Number of cores | 4 | Low smoke according to EN 61034-2 | No |
Insulation | XLPE (VPE) | Insulation retention | No |
Conductor coding | Color | Functional safety | No |
Yellow / green wire | No | Outside diamter approx |
15.5 mm |
Screen | Yes | Max. permisble conductor temperature | 90 °C |
Litze | Yes | Min / Max installation temperature | 0 - 60 °C |
Numbers of auxiliary cores | 0 | Min / Max operating temperature | -20 - 90 °C |
Nominal cross-section conductor | 0 mm2 | Nominal voltage U0 | 0.6 kV |
Lead jacket | No | Nominal voltage U | 1 kV |