Benefits Dorot 80-valve:
- Increased capacity and reduced pressure loss
- Insensitive to pollution because of a large inlet filter
- insensitive to pollution by large inlet filter
- Large passages for control pressure, using labyrinth (2-way)
- Set Screw (throttle) for capacity control
- Improved control characteristic
- Non-return flap prevents opening after the pressure releases(2-way)
- Large, easy to operate manual control, 3 positions: open-close automatically. Close of with energized coil, Manually closing 
- Easy to build a pressure reducing pilot directly into the valve
- Nuts stuck in there housing, can't lose them.
- Available in 2-way and 3-way version
- Easy conversion to 2- of 3-weg
 
Technical data:

Version1"/1.1 2"; 2"
2-way; 3-way; basic
Odds and law
Max pressure10

Max capacity

40 m3/ hour
Max temperature60 °C (with decreasing pressure)
Voltage24VAC-DC; 230
Power (agr. coil) 24 VAC: 2,2 W: 24 VDC 4,5 W
Tekst (Ind. coil - G80)24 VAC: 7.5W: DC: 6.5W

Dorot 75ST - 2 way - 24VAC

Item No.017600914
Log in for your personal and competitive prices
Don't have an account yet? Create an account.
​​​​Royal Brinkman does not provide their services to any company outside of the horticulture.​​​​
​​ Login and request a quotation for multiple products​​​​​​​​
Worldwide delivery options
Premium products for your cultivation

Description

Benefits Dorot 80-valve:
- Increased capacity and reduced pressure loss
- Insensitive to pollution because of a large inlet filter
- insensitive to pollution by large inlet filter
- Large passages for control pressure, using labyrinth (2-way)
- Set Screw (throttle) for capacity control
- Improved control characteristic
- Non-return flap prevents opening after the pressure releases(2-way)
- Large, easy to operate manual control, 3 positions: open-close automatically. Close of with energized coil, Manually closing 
- Easy to build a pressure reducing pilot directly into the valve
- Nuts stuck in there housing, can't lose them.
- Available in 2-way and 3-way version
- Easy conversion to 2- of 3-weg
 
Technical data:

Version1"/1.1 2"; 2"
2-way; 3-way; basic
Odds and law
Max pressure10

Max capacity

40 m3/ hour
Max temperature60 °C (with decreasing pressure)
Voltage24VAC-DC; 230
Power (agr. coil) 24 VAC: 2,2 W: 24 VDC 4,5 W
Tekst (Ind. coil - G80)24 VAC: 7.5W: DC: 6.5W