Yellow/green core | Yes | Armament | No |
Sheath colour | Grey | Screen | No |
Nom. conductive section | 185 mm² | Nom. section concentric core | 0 mm² |
Number of cores | 5 | Nom. section auxiliary core | 0 mm² |
Max. permissible guide temperature | 90 °C | Permitted cable temperature, in motion | 0 - 80 °C |
Concentric conductor | None | Number of auxiliary cores | 0 |
Euroclass burning falling droplets/particles | D2 | Nom. Voltage U | 1 kV |
Halogen free according to EN 60754-1/2 | No | Eurobrand class according to EN 13501-6 | Dca |
Low smoke according to EN 61034-2 | No | Jacket material | polyvinyl chloride (PVC) |
Fire retardant | According EN 60332-3-24 | Nom. Tension U0 | 0.6 kV |
Conductor assembly | Class 2 = mingled | Euroclass corrosion/acidity grade according to EN 13501-6-6 | A3 |
Conductor material | Copper, white | Permitted cable outside temperature, fixed mounted | -40 - 80 °C |
Euroclass smoke production according to EN 13501-6 | S3 | Core isolation | XLPE (VPE) |
Core coding | Colour | Lead jacket | No |
Conductor shape | Round | Flex | No |
Outer diametercirca | Circa 55.1mm | Function retention | No |
Isolation maintenance | No |
Installation cable YMvK 5x185 mm Dca rss -D- 0,6/1kV gy

Item No.080100830
Royal Brinkman does not provide their services to any company outside of the horticulture.
✔ Login and request a quotation for multiple products
✔ Worldwide delivery options
✔ Premium products for your cultivation
Description
Yellow/green core | Yes | Armament | No |
Sheath colour | Grey | Screen | No |
Nom. conductive section | 185 mm² | Nom. section concentric core | 0 mm² |
Number of cores | 5 | Nom. section auxiliary core | 0 mm² |
Max. permissible guide temperature | 90 °C | Permitted cable temperature, in motion | 0 - 80 °C |
Concentric conductor | None | Number of auxiliary cores | 0 |
Euroclass burning falling droplets/particles | D2 | Nom. Voltage U | 1 kV |
Halogen free according to EN 60754-1/2 | No | Eurobrand class according to EN 13501-6 | Dca |
Low smoke according to EN 61034-2 | No | Jacket material | polyvinyl chloride (PVC) |
Fire retardant | According EN 60332-3-24 | Nom. Tension U0 | 0.6 kV |
Conductor assembly | Class 2 = mingled | Euroclass corrosion/acidity grade according to EN 13501-6-6 | A3 |
Conductor material | Copper, white | Permitted cable outside temperature, fixed mounted | -40 - 80 °C |
Euroclass smoke production according to EN 13501-6 | S3 | Core isolation | XLPE (VPE) |
Core coding | Colour | Lead jacket | No |
Conductor shape | Round | Flex | No |
Outer diametercirca | Circa 55.1mm | Function retention | No |
Isolation maintenance | No |