YMVkas cable 4 x 10 mm

Item No.080101402
Royal Brinkman does not provide their services to any companies outside of horticulture.
Log in for your personal and competitive prices
Don't have an account yet? Create an account.
​​ Login and request a quotation for mulitple products​​​​​​​​
Worldwide delivery options
Premium products for your cultivation

Description

ClassInstallation cableNominal cross-section concentric conductor0 mm2
Series / programVG-YMvKas mbArmingYes
Conductor material Copper, bareOuter jacket materialPVC
Nominal conductor cross-section10 mm2Jacket colorGrey
Conductor structureClass 2 = collapsedHalogene free according to EN 50267-2-2No
Conductor shapeRoundFire retardant according to EN 60332-3-24Yes
Number of cores4Low smoke according to EN 61034-2No
InsulationXLPE (VPE)Insulation retentionNo
Conductor codingColorFunctional safetyNo
Yellow /  green wireNoOutside diamter approx

24.2 mm

ScreenYesMax. permisble conductor temperature90 °C
LitzeYesMin / Max installation temperature0 - 60 °C
Numbers of auxiliary cores0Min / Max operating temperature-20 - 90 °C
Nominal cross-section conductor0 mm2Nominal voltage U00.6 kV
Lead jacketNoNominal voltage U

1 kV

Concentric conductorNoneDiscount group                1350                              

YMVkas cable 4 x 10 mm

Item No.080101402
Log in for your personal and competitive prices
Don't have an account yet? Create an account.
​​​​Royal Brinkman does not provide their services to any company outside of the horticulture.​​​​
​​ Login and request a quotation for multiple products​​​​​​​​
Worldwide delivery options
Premium products for your cultivation

Description

ClassInstallation cableNominal cross-section concentric conductor0 mm2
Series / programVG-YMvKas mbArmingYes
Conductor material Copper, bareOuter jacket materialPVC
Nominal conductor cross-section10 mm2Jacket colorGrey
Conductor structureClass 2 = collapsedHalogene free according to EN 50267-2-2No
Conductor shapeRoundFire retardant according to EN 60332-3-24Yes
Number of cores4Low smoke according to EN 61034-2No
InsulationXLPE (VPE)Insulation retentionNo
Conductor codingColorFunctional safetyNo
Yellow /  green wireNoOutside diamter approx

24.2 mm

ScreenYesMax. permisble conductor temperature90 °C
LitzeYesMin / Max installation temperature0 - 60 °C
Numbers of auxiliary cores0Min / Max operating temperature-20 - 90 °C
Nominal cross-section conductor0 mm2Nominal voltage U00.6 kV
Lead jacketNoNominal voltage U

1 kV

Concentric conductorNoneDiscount group                1350