Description
• Beneficial and simple level measurement
• Pressurec compensation with built-in capillary with filter
• Lower wiring when used as a two wire circuit
• High overall accuracy and long lasting stability
• Robust stainless steel housing with high density
Application
Execution | Hanging pressure sensor equipped with pressure compensation compression capillary | Pressure ressistance[bar] | 4 |
Media | Fluid media | Min. bursting pressure[bar] | 4,8 |
Medium temperature[°C] | -10...50 | Pressure sort | Relative pressure |
Electrical characteristics
Power supply[V] | 10 ...30 DC | Reverse protected | Yes |
Protection class | III |
Outlets
Total number of outlets | 1 | Analogue outlet current[mA] | 4...20 |
Outlet signal | Analogue signal | Max. pressure[Ω] | 700; (Ub = 24 V; (Ub - 10 V) x 50) |
Number of anologue outlets | 1 | Short circuit protection | Yes |
Measurement / adjustment range
Measuring range[bar] | 0...0,6 |
Accurate / deviations
Repeat accuracy [X21] | < 0,1; (at temperature changes, 10 K) | Prolonged stability [X21] | < 0,2; (each year) |
Characteristic deviation [X21] | < 0,5 (BFSL) / 1; (incl. linearity, zero point, and scale error (limit setting) | Temperature coefficient zero [X22] | < ± 0,2; (0... 50 °C) |
Deviation linearity[X21] | < 0,2 (BFSL) | Temperature coefficient measuring range [X22] | < ± 0,2; (0... 50 °C) |
Environmental variables
Ambient temperature [°C] | -10...50 | Protection class | IP68 |
Storage temperature [°C] | -30...80 |
Admissions / tests
MTTF [ANN] | 732 |
Mechanical characteristics
Weight [g] | 920,6 | Materials | 1.4571 (Stainless steel / 316Ti); PA (polyamide) |
Remarks
Packaging unit | 1 piece |
Electrical connection
Connection | Kabel: 10 m, PUR, Ø 7,5mm;, PVC |
Pressure notifier water level 0-6mwk

Description
• Beneficial and simple level measurement
• Pressurec compensation with built-in capillary with filter
• Lower wiring when used as a two wire circuit
• High overall accuracy and long lasting stability
• Robust stainless steel housing with high density
Application
Execution | Hanging pressure sensor equipped with pressure compensation compression capillary | Pressure ressistance[bar] | 4 |
Media | Fluid media | Min. bursting pressure[bar] | 4,8 |
Medium temperature[°C] | -10...50 | Pressure sort | Relative pressure |
Electrical characteristics
Power supply[V] | 10 ...30 DC | Reverse protected | Yes |
Protection class | III |
Outlets
Total number of outlets | 1 | Analogue outlet current[mA] | 4...20 |
Outlet signal | Analogue signal | Max. pressure[Ω] | 700; (Ub = 24 V; (Ub - 10 V) x 50) |
Number of anologue outlets | 1 | Short circuit protection | Yes |
Measurement / adjustment range
Measuring range[bar] | 0...0,6 |
Accurate / deviations
Repeat accuracy [X21] | < 0,1; (at temperature changes, 10 K) | Prolonged stability [X21] | < 0,2; (each year) |
Characteristic deviation [X21] | < 0,5 (BFSL) / 1; (incl. linearity, zero point, and scale error (limit setting) | Temperature coefficient zero [X22] | < ± 0,2; (0... 50 °C) |
Deviation linearity[X21] | < 0,2 (BFSL) | Temperature coefficient measuring range [X22] | < ± 0,2; (0... 50 °C) |
Environmental variables
Ambient temperature [°C] | -10...50 | Protection class | IP68 |
Storage temperature [°C] | -30...80 |
Admissions / tests
MTTF [ANN] | 732 |
Mechanical characteristics
Weight [g] | 920,6 | Materials | 1.4571 (Stainless steel / 316Ti); PA (polyamide) |
Remarks
Packaging unit | 1 piece |
Electrical connection
Connection | Kabel: 10 m, PUR, Ø 7,5mm;, PVC |