U/FTP Cable cat6A 4x2 solid - reel 305 mtr

Item No.080133455
Royal Brinkman does not provide their services to any companies outside of horticulture.
Log in for your personal and competitive prices
Don't have an account yet? Create an account.
​​ Login and request a quotation for mulitple products​​​​​​​​
Worldwide delivery options
Premium products for your cultivation

Description

The Cat. Gigamedia's 6A-cables are tested to 550 MHz, certified by an independent laboratory (3P), specifically designed to exceed Class EA specifications and support Ethernet applications up to 10 Gbps, such as PoE (remote power, according to IEEE 802.3af/at). Separate shielding for each pair of wires ensures low Next and optimal bandwidth.

Features

  • Standard complinance: ISO/IEC 11801, EN 50173, ISO/IEC 24764, IEC 61156-5,  ANSI/TIA-568-C.2;
  • Application: IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T en 10GBase-T IEEE 802.3at/af(PoE/PoE+);
  • Mantel color:  White (RAL 9003);
  • Diameter external mantel: 7,3 mm.;
  • LS0H-mantel (IEC 60754-2 en IEC 61034-2);
  • Fire behaviour: EN 13501-6 : Dca, s2, d2, a2 EN 50575, EN 50399, EN 60332-1-2.

Technical specifications / Data- and communication cable

Numbers of conductors8TwistedPair
Conductor codingColor

Halogen free according EN 60754-1/2

Yes
Conductor coding according to HD 308 S2YesMantel colorWhite
Collective protectionNoneNominal conductor diameter0.574 mm
Protecteting groupsFoilNominal conductor cross-section0.259 mm 2

AWG-size

23NVP value74%
Smoke retardantAccording EN 60332-1-2Conductor surfaceWhite
External mantel diameter7.8 mmLow smoke according EN 61034-2Yes
Categorie6A (TIA)CableBundel
Euro fire class according EN 13501-6DcaConductor constructionClass 1 = solid
Euroclass burning droplets/particles according to EN 1d2Permissible cable outlet temperature after installation without vibration

-20 - 60 °C

Euroclass corrosivity/acidity in accordance EN 13501-6a2Permissible cable outlet temperature during installation

0 - 50 °C

Euroclass in smoke development according EN 13501-6s2Installation in soil/subsoilNone
Conductor materialCopper

U/FTP Cable cat6A 4x2 solid - reel 305 mtr

Item No.080133455
Log in for your personal and competitive prices
Don't have an account yet? Create an account.
​​​​Royal Brinkman does not provide their services to any company outside of the horticulture.​​​​
​​ Login and request a quotation for multiple products​​​​​​​​
Worldwide delivery options
Premium products for your cultivation

Description

The Cat. Gigamedia's 6A-cables are tested to 550 MHz, certified by an independent laboratory (3P), specifically designed to exceed Class EA specifications and support Ethernet applications up to 10 Gbps, such as PoE (remote power, according to IEEE 802.3af/at). Separate shielding for each pair of wires ensures low Next and optimal bandwidth.

Features

  • Standard complinance: ISO/IEC 11801, EN 50173, ISO/IEC 24764, IEC 61156-5,  ANSI/TIA-568-C.2;
  • Application: IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T en 10GBase-T IEEE 802.3at/af(PoE/PoE+);
  • Mantel color:  White (RAL 9003);
  • Diameter external mantel: 7,3 mm.;
  • LS0H-mantel (IEC 60754-2 en IEC 61034-2);
  • Fire behaviour: EN 13501-6 : Dca, s2, d2, a2 EN 50575, EN 50399, EN 60332-1-2.

Technical specifications / Data- and communication cable

Numbers of conductors8TwistedPair
Conductor codingColor

Halogen free according EN 60754-1/2

Yes
Conductor coding according to HD 308 S2YesMantel colorWhite
Collective protectionNoneNominal conductor diameter0.574 mm
Protecteting groupsFoilNominal conductor cross-section0.259 mm 2

AWG-size

23NVP value74%
Smoke retardantAccording EN 60332-1-2Conductor surfaceWhite
External mantel diameter7.8 mmLow smoke according EN 61034-2Yes
Categorie6A (TIA)CableBundel
Euro fire class according EN 13501-6DcaConductor constructionClass 1 = solid
Euroclass burning droplets/particles according to EN 1d2Permissible cable outlet temperature after installation without vibration

-20 - 60 °C

Euroclass corrosivity/acidity in accordance EN 13501-6a2Permissible cable outlet temperature during installation

0 - 50 °C

Euroclass in smoke development according EN 13501-6s2Installation in soil/subsoilNone
Conductor materialCopper