U/FTP Cable cat6A 4x2 solid - reel 305 mtr
Description
The Cat. Gigamedia's 6A-cables are tested to 550 MHz, certified by an independent laboratory (3P), specifically designed to exceed Class EA specifications and support Ethernet applications up to 10 Gbps, such as PoE (remote power, according to IEEE 802.3af/at). Separate shielding for each pair of wires ensures low Next and optimal bandwidth.
Features
-
Standard complinance: ISO/IEC 11801, EN 50173, ISO/IEC 24764, IEC 61156-5, ANSI/TIA-568-C.2;
-
Application: IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T en 10GBase-T IEEE 802.3at/af(PoE/PoE+);
-
Mantel color: White (RAL 9003);
-
Diameter external mantel: 7,3 mm.;
-
LS0H-mantel (IEC 60754-2 en IEC 61034-2);
-
Fire behaviour: EN 13501-6 : Dca, s2, d2, a2 EN 50575, EN 50399, EN 60332-1-2.
Technical specifications / Data- and communication cable
Numbers of conductors | 8 | Twisted | Pair |
Conductor coding | Color |
Halogen free according EN 60754-1/2 | Yes |
Conductor coding according to HD 308 S2 | Yes | Mantel color | White |
Collective protection | None | Nominal conductor diameter | 0.574 mm |
Protecteting groups | Foil | Nominal conductor cross-section | 0.259 mm 2 |
AWG-size | 23 | NVP value | 74% |
Smoke retardant | According EN 60332-1-2 | Conductor surface | White |
External mantel diameter | 7.8 mm | Low smoke according EN 61034-2 | Yes |
Categorie | 6A (TIA) | Cable | Bundel |
Euro fire class according EN 13501-6 | Dca | Conductor construction | Class 1 = solid |
Euroclass burning droplets/particles according to EN 1 | d2 | Permissible cable outlet temperature after installation without vibration |
-20 - 60 °C |
Euroclass corrosivity/acidity in accordance EN 13501-6 | a2 | Permissible cable outlet temperature during installation |
0 - 50 °C |
Euroclass in smoke development according EN 13501-6 | s2 | Installation in soil/subsoil | None |
Conductor material | Copper |
U/FTP Cable cat6A 4x2 solid - reel 305 mtr
Description
The Cat. Gigamedia's 6A-cables are tested to 550 MHz, certified by an independent laboratory (3P), specifically designed to exceed Class EA specifications and support Ethernet applications up to 10 Gbps, such as PoE (remote power, according to IEEE 802.3af/at). Separate shielding for each pair of wires ensures low Next and optimal bandwidth.
Features
-
Standard complinance: ISO/IEC 11801, EN 50173, ISO/IEC 24764, IEC 61156-5, ANSI/TIA-568-C.2;
-
Application: IEEE 802.3 10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T en 10GBase-T IEEE 802.3at/af(PoE/PoE+);
-
Mantel color: White (RAL 9003);
-
Diameter external mantel: 7,3 mm.;
-
LS0H-mantel (IEC 60754-2 en IEC 61034-2);
-
Fire behaviour: EN 13501-6 : Dca, s2, d2, a2 EN 50575, EN 50399, EN 60332-1-2.
Technical specifications / Data- and communication cable
Numbers of conductors | 8 | Twisted | Pair |
Conductor coding | Color |
Halogen free according EN 60754-1/2 | Yes |
Conductor coding according to HD 308 S2 | Yes | Mantel color | White |
Collective protection | None | Nominal conductor diameter | 0.574 mm |
Protecteting groups | Foil | Nominal conductor cross-section | 0.259 mm 2 |
AWG-size | 23 | NVP value | 74% |
Smoke retardant | According EN 60332-1-2 | Conductor surface | White |
External mantel diameter | 7.8 mm | Low smoke according EN 61034-2 | Yes |
Categorie | 6A (TIA) | Cable | Bundel |
Euro fire class according EN 13501-6 | Dca | Conductor construction | Class 1 = solid |
Euroclass burning droplets/particles according to EN 1 | d2 | Permissible cable outlet temperature after installation without vibration |
-20 - 60 °C |
Euroclass corrosivity/acidity in accordance EN 13501-6 | a2 | Permissible cable outlet temperature during installation |
0 - 50 °C |
Euroclass in smoke development according EN 13501-6 | s2 | Installation in soil/subsoil | None |
Conductor material | Copper |