Description
Benefits Dorot 80-valve:
- Increased capacity and reduced pressure loss
- Insensitive to pollution because of a large inlet filter
- insensitive to pollution by large inlet filter
- Large passages for control pressure, using labyrinth (2-way)
- Set Screw (throttle) for capacity control
- Improved control characteristic
- Non-return flap prevents opening after the pressure releases(2-way)
- Large, easy to operate manual control, 3 positions: open-close automatically. Close of with energized coil, Manually closing
- Easy to build a pressure reducing pilot directly into the valve
- Nuts stuck in there housing, can't lose them.
- Available in 2-way and 3-way version
- Easy conversion to 2- of 3-weg
Technical data:
| Version | 1"/1.1 2"; 2" 2-way; 3-way; basic Odds and law |
| Max pressure | 10 |
|
Max capacity | 40 m3/ hour |
| Max temperature | 60 °C (with decreasing pressure) |
| Voltage | 24VAC-DC; 230 |
| Power (agr. coil) | 24 VAC: 2,2 W: 24 VDC 4,5 W |
| Tekst (Ind. coil - G80) | 24 VAC: 7.5W: DC: 6.5W |
Dorot 75ST - 2 way - 24VAC

Description
Benefits Dorot 80-valve:
- Increased capacity and reduced pressure loss
- Insensitive to pollution because of a large inlet filter
- insensitive to pollution by large inlet filter
- Large passages for control pressure, using labyrinth (2-way)
- Set Screw (throttle) for capacity control
- Improved control characteristic
- Non-return flap prevents opening after the pressure releases(2-way)
- Large, easy to operate manual control, 3 positions: open-close automatically. Close of with energized coil, Manually closing
- Easy to build a pressure reducing pilot directly into the valve
- Nuts stuck in there housing, can't lose them.
- Available in 2-way and 3-way version
- Easy conversion to 2- of 3-weg
Technical data:
| Version | 1"/1.1 2"; 2" 2-way; 3-way; basic Odds and law |
| Max pressure | 10 |
|
Max capacity | 40 m3/ hour |
| Max temperature | 60 °C (with decreasing pressure) |
| Voltage | 24VAC-DC; 230 |
| Power (agr. coil) | 24 VAC: 2,2 W: 24 VDC 4,5 W |
| Tekst (Ind. coil - G80) | 24 VAC: 7.5W: DC: 6.5W |


Nederland
Arabic ( العربية)
Asia
Australia
Canada
Can-Hub
Česko
Chile
China ( 中国 )
Deutsch
Español
Français
Hortispares
Italy
Japan
Magyar
Mexico
Polski
Portugal
Russian
Scandinavia
Türkçe
United Kingdom
United States
Ireland
Africa
Arabic ( العربية)
Asia
Australia
Canada
Can-Hub
Česko
Chile
China ( 中国 )
Deutsch
Español
Français
Hortispares
Italy
Japan
Magyar
Mexico
Nederlands
Polski
Portugal
Russian
Scandinavia
Türkçe
United Kingdom
United States